Hanna-instruments HI 5000 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Měřící nástroje Hanna-instruments HI 5000. Hanna Instruments HI 5000 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 36
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Instruction Manual
http://www.hannainst.com
These Instruments are in
Compliance with the CE Directives
A
L
A
R
M
L
I
N
E
S
E
T
E
C
S
E
T
p
H
pH
0
SE
C
O
N
D
S
m
S
2
.0 0
TIM
E
R
M
IN
U
TE
S
90
P
R
O
P
O
R
TIO
N
A
L S
ET
T
IN
G
S
4
0
S
E
C
O
N
D
S
pH
2.0
0
T
IM
E
R
M
IN
U
T
ES
90
P
R
O
P
O
R
T
IO
N
A
L S
E
TT
IN
G
S
1
S
LO
P
E C
A
L
A
LA
R
M
ON
OFF
0.5 1.5
S
E
T
F
E
R
T
m
S
O
FF
S
ET
S
L
O
P
E
A
LA
R
M
ON
OFF
0.5 1.5
S
E
T
AC
ID
ALA
HI 991
1
10
2
.5
5
7.5
1
10
2.5
5
7.5
ALA
p
H
5
EC
m
S
F
E
F
EE
2
3
AC
ID
A
LK
pH
0
1
2
0
1
2
m
S
A
L
A
R
M
Z
E
R
O
C
A
L
HI 9913 - HI 9923
HI 9935
Wall Mounted Dual
Conductivity/TDS &
pH Controllers
Zobrazit stránku 0
1 2 3 4 5 6 ... 35 36

Shrnutí obsahu

Strany 1 - HI 9913 - HI 9923

Instruction Manualhttp://www.hannainst.comThese Instruments are inCompliance with the CE DirectivesALARMLINESET ECSET pHpH0SECONDSmS2.0 0TIMERMINUTES9

Strany 2 - TABLE OF CONTENTS

1026272823. 110/115V or 220/240V power configuration24. Incoming power terminals25. FusesBOTTOM VIEW26. Female BNC connector for a combination pH elec

Strany 3

11Specifications HI 9923RANGE 0.00 to 14.00 pH and 0.00 to 10.00 mS/cm (mmho/cm)RESOLUTION 0.01 pH and 0.01 mS/cm (mmho/cm)ACCURACY ±0.02 pH and ±2%

Strany 4 - MECHANICAL LAYOUTS

12pH0SECONDSppm400 0TIMERMINUTES90PROPORTIONAL SETTINGS470SECONDSpH2.00TIMERMINUTES90PROPORTIONAL SETTINGS900 1800SLOPE CALALARMONOFF100 300SETFERTppm

Strany 5 - 221.8 mm

1321. Powered dosage terminals (Relay) for pH correction22. Powered dosage terminals (Relay) for TDS correction23. 110/115V or 220/240V power configur

Strany 6 - FUNCTIONAL DIAGRAM HI 9913

14CONNECTIONS & WIRINGCONNECTIONS & WIRINGCONNECTIONS & WIRINGCONNECTIONS & WIRINGCONNECTIONS & WIRINGSpecifications HI 9935RANGE

Strany 7

15• Unscrew the 4 screws on the right hand panel and remove thecover and the gasket. Thread the wires through the access portson the right hand side o

Strany 8

16CONDUCTIVITY/TDS PROBE CONNECTION• Attach the conductivity/TDS probe (HI 3002, HI 3001D orHI 7638) to the DIN socket located on the bottom of the ca

Strany 9 - FUNCTIONAL DIAGRAM HI 9923

17pH012012mSALARMpH0SECONDSmS2.0 0TIMERMINUTES90PROPORTIONAL SETTINGS470SECONDSpH2.00TIMERMINUTES90PROPORTIONAL SETTINGS14SLOPE CALALARMONOFF0.5 1.5SE

Strany 10 - BOTTOM VIEW

18• The alarm is also activated if one or both of the independentmaximum dosage times are exceeded. Themaximum time that the relay contacts remainacti

Strany 11

19NORMAL OPERATION &NORMAL OPERATION &NORMAL OPERATION &NORMAL OPERATION &NORMAL OPERATION &MEASUREMENTMEASUREMENTMEASUREMENTMEASU

Strany 12 - FUNCTIONAL DIAGRAM HI 9935

2ISO 9000 CertifiedCompany since 1992TABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTSDear Customer,Thank you for

Strany 13 - BOTTOM VEW

20pH pH pH pH pH CALIBRATIONCALIBRATIONCALIBRATIONCALIBRATIONCALIBRATIONMake sure that the pH electrode and any ground probe have beenproperly connec

Strany 14 - CONNECTIONS & WIRING

21• If the temperature of the buffer solution is not 25°C (77°F), refer tothe chart at the end of the manual for the appropriate buffer valueat a give

Strany 15 - USING MATCHING PIN

22ments are in the 1.2 to 2.5 EC range. Similarly, utilizeHI 7039L with a value of 5.00 mS/cm at 25 °C if controlling yourprocess with HI 9923 and HI

Strany 16 - ALARM CONNECTIONS

2347SETACID56FEEDADJUSTEMENT OF SETPOINTSADJUSTEMENT OF SETPOINTSADJUSTEMENT OF SETPOINTSADJUSTEMENT OF SETPOINTSADJUSTEMENT OF SETPOINTSACIDALK14SETF

Strany 17 - AN ALARM CONDITION

240SECONDSmS2.0 090PROPORTIONAL SETTINGS0.5 1.5In order to optimize the controlling process and reduce the amount ofchemicals and fertilizers used, it

Strany 18 - MAIN POWER SUPPLY CONNECTION

25e.g. EC proportional control for HI 9913Setpoint = 2.20 mS/cm (EC)Measured value = 1.45 mS/cmDelta = 2.20 - 1.45 = 0.75 mS/cmProportional settings

Strany 19

26D ppmSeconds15 30 45605010015020015 30 45 60e.g. HI 9935 proportional controlSetpoint = 1600 ppm (TDS)Measured value = 1550 ppmDelta = 1600 - 1550 =

Strany 20 - OFFSET ADJUSTMENT:

27pH VALUES AT VARIOUSpH VALUES AT VARIOUSpH VALUES AT VARIOUSpH VALUES AT VARIOUSpH VALUES AT VARIOUSTEMPERATURESTEMPERATURESTEMPERATURESTEMPERATURES

Strany 21 - ZERO ADJUSTMENT:

28pH ELECTRODE CONDITIONINGpH ELECTRODE CONDITIONINGpH ELECTRODE CONDITIONINGpH ELECTRODE CONDITIONINGpH ELECTRODE CONDITIONING& MAINTENANCE&

Strany 22 - ZERO CAL

29TROUBLESHOOTINGEvaluate your electrode performance based on the following.• Noise (Readings fluctuate up and down) could be due toclogged/dirty jun

Strany 23 - ADJUSTEMENT OF SETPOINTS

3PRELIMINARY EXAMINATIONPRELIMINARY EXAMINATIONPRELIMINARY EXAMINATIONPRELIMINARY EXAMINATIONPRELIMINARY EXAMINATIONGENERAL DESCRIPTIONGENERAL DESCRIP

Strany 24

30CLEANING PROCEDURERemove the sleeve and soak the probe in a Hanna HI 7061 GeneralCleaning Solution for 1 hour.If the probe has been left in highly c

Strany 25

31The conventional electrodes may be used for indoor applications butthe cable length should not exceed 10 m (33').MEDIUM DISTANCE, INDOOR/OUTDOO

Strany 26 - DEAD BAND

32HI 3002 FOR IN-LINE INSTALLATIONThe drawing illustrates the ideal installation system since the streampressure in the pipe forces the air bubbles ou

Strany 27

33ACCESSORIESACCESSORIESACCESSORIESACCESSORIESACCESSORIESpH ELECTRODESHI 1002/3 Double Teflon junction with external threadsHI 1003/3 Double Teflon ju

Strany 28 - CLEANING PROCEDURE

34All Hanna controllers are warranted for two years againstdefects in workmanship and materials when used for their intendedpurpose and maintained acc

Strany 29 - TROUBLESHOOTING

35CE DECLARATION OF CONFORMITYCE DECLARATION OF CONFORMITYCE DECLARATION OF CONFORMITYCE DECLARATION OF CONFORMITYCE DECLARATION OF CONFORMITYDECLARAT

Strany 30

MAN9913 10/99http://www.hannainst.comHANNA LITERATUREHANNA LITERATUREHANNA LITERATUREHANNA LITERATUREHANNA LITERATUREPRINTED IN PORTUGALHanna publish

Strany 31 - INSTALLATION

4pH012012mSALARMpH0SECONDSmS2.0 0TIMERMINUTES90PROPORTIONAL SETTINGS470SECONDSpH2.00TIMERMINUTES90PROPORTIONAL SETTINGS14SLOPE CALALARMONOFF0.5 1.5SET

Strany 32 - HI 3002 FOR TANK INSTALLATION

53.8“96.9 mm25 mm1“75 mm3“Fig. 3227.8 mm9“188.6 mm7.4“221.8 mm8.7“174.8 mm6.9“Fig. 4Figure 3 is a dimensioned, bottom view of the wall mountedcontroll

Strany 33 - ACCESSORIES

6FUNCTIONAL DIAGRAM HI 9913FUNCTIONAL DIAGRAM HI 9913FUNCTIONAL DIAGRAM HI 9913FUNCTIONAL DIAGRAM HI 9913FUNCTIONAL DIAGRAM HI 9913pH012012mSALARMpH0S

Strany 34 - WARRANTY

7Unplug the instrument from the power supply beforewiring or replacing the fuses.26272820. Triple contact alarm in a Normally Closed (NC) or a Normall

Strany 35 - CE DECLARATION OF CONFORMITY

8Specifications HI 9913RANGE 0.00 to 14.00 pH and 0.00 to 10.00 mS/cm (EC)RESOLUTION 0.01 pH and 0.01 mS/cmACCURACY ±0.02 pH and ±2% F. S.(@20°C/68°F)

Strany 36 - PRINTED IN PORTUGAL

9FUNCTIONAL DIAGRAM HI 9923FUNCTIONAL DIAGRAM HI 9923FUNCTIONAL DIAGRAM HI 9923FUNCTIONAL DIAGRAM HI 9923FUNCTIONAL DIAGRAM HI 9923pH0mS0.50m TIMERSMI

Příbuzné modely HI 9913 | HI 9923 | HI 9935 |

Komentáře k této Příručce

Žádné komentáře