Hanna-instruments HI 9912 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Měřící nástroje Hanna-instruments HI 9912. Hanna Instruments HI 9912 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 28
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Instruction Manual
HI 9912
Wall Mounted
Dual pH/ORP
Controller
http://www.hannainst.com
These Instruments are in
Compliance with the CE Directives
A
L
A
R
M
L
IN
E
S
E
T
O
R
P
S
E
T
p
H
0
S
E
C
O
N
D
S
m
V
2
0
0
0
O
R
P
T
I
M
E
R
M
I
N
U
T
E
S
9
0
P
R
O
P
O
R
T
I
O
N
A
L
S
E
T
T
I
N
G
S
1
1
0
2
.
5
5
7
.
5
0
S
E
C
O
N
D
S
p
H
2
.
0
0
pH
T
I
M
E
R
M
I
N
U
T
E
S
9
0
P
R
O
P
O
R
T
I
O
N
A
L
S
E
T
T
I
N
G
S
1
1
0
2
.5
5
7
.
5
1
0
0
5
0
C
A
L
A
L
A
R
M
ON
OFF
5
0
1
5
0
S
E
T
R
D
X
mV
O
F
F
S
E
T
S
L
O
P
E
A
L
A
R
M
O
N
O
F
F
0
.
5
1
.
5
p
H
H
I 9
9
mV
ORP
3
S
E
T
ACID
A
L
2
F
E
3
0
0
pH
0
1
2
0
100
200
m
V
ALAR
M
Zobrazit stránku 0
1 2 3 4 5 6 ... 27 28

Shrnutí obsahu

Strany 1 - Controller

Instruction ManualHI 9912Wall MountedDual pH/ORPControllerhttp://www.hannainst.comThese Instruments are inCompliance with the CE DirectivesALARMLINESE

Strany 2 - TABLE OF CONTENTS

10pH0120100200mVALARMpH0SECONDSmV2000TIMERMINUTES90PROPORTIONAL SETTINGS1102.557.50SECONDSpH2.00TIMERMINUTES90PROPORTIONAL SETTINGS1102.557.5500900CAL

Strany 3

11ALARM DOSING TIMEMINUTES1102.557.5ALARMONOFFMAIN POWER SUPPLY CONNECTION•BeforeBeforeBeforeBeforeBefore connecting the unit to the mains, make sure

Strany 4 - MECHANICAL LAYOUTS

12Make sure that the controller has been properly calibrated beforecommencing and that the pH and ORP setpoint(s) have beenadjusted (see the following

Strany 5 - 174.8 mm

13pHOFFSET SLOPEALARMONOFF7.014cm(1½")HI 70074cm(1½")HI 70074cm(1½")HI 7007Make sure that the pH electrode and any ground probe have be

Strany 6 - FUNCTIONAL DIAGRAM HI 9912

144cm(1½")HI 7010pHOFFSET SLOPEALARMONOFF10.01SLOPE ADJUSTMENT:• Rinse the electrode (and ground probe)thoroughly with water and immersethe botto

Strany 7 - BOTTOM VIEW

15Make sure that the electrode (and any ground probe) is properlyinstalled and calibrated (see the preceding pages).FOR pHSimply turn the pH ACID FEE

Strany 8

160SECONDSpH2.0090PROPORTIONAL SETTINGS0.5 1.5D pHSeconds15 30 45600.250.500.751.001.251.501.752.0015 30 45 60D pHSeconds15 30 45600.250.500.751.001.2

Strany 9 - CONNECTIONS & WIRING

17ALARM DOSING TIMEMINUTES1102.557.5e.g. ORP proportional controlSetpoint = 750 mVMeasured value = 725 mVDelta = 750 - 725 = 25 mVProportional setting

Strany 10 - RELAY CONNECTIONS

18Please refer to the following chart for a more accurate pH calibra-tion:For instance, if the buffer temperature is 25°C (77°F), calibrate themeter t

Strany 11 - MAIN POWER SUPPLY CONNECTION

19REDOX MEASUREMENTREDOX MEASUREMENTREDOX MEASUREMENTREDOX MEASUREMENTREDOX MEASUREMENTRedox measurements allow the quantification of the oxidizing or

Strany 12

2TABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTSDear Customer,Thank you for choosing a Hanna Product.Please read

Strany 13 - OFFSET ADJUSTMENT:

20The protective cap should also be filled with a few drops of HI 70300storage solution if the electrode is not being used at all.Note: With industria

Strany 14 - ORP CALIBRATION

21For more specific cleaning procedures, refer to the electrode’s instruc-tion manual.IMPORTANT: After performing any of the cleaning procedures rinse

Strany 15 - DOSING DIRECTION

22This type of connection is very delicate and requires constant attentionto maintain proper operating conditions.The conventional electrodes may be u

Strany 16

23pH CALIBRATION SOLUTIONSHI 7004L pH 4.01 buffer solution, 460 mLHI 7007L pH 7.01 buffer solution, 460 mLHI 7010L pH 10.01 buffer solution, 460 mLORP

Strany 18

25All Hanna controllers are warranted for two years againstdefects in workmanship and materials when used for their intendedpurpose and maintained acc

Strany 19 - REDOX MEASUREMENT

26• CABLES AND CONNECTORS• CALIBRATION AND MAINTENANCE SOLUTIONS• CHEMICAL TEST KITS• CHLORINE METERS• CONDUCTIVITY/TDS METERS• DISSOLVED OXYGEN METER

Strany 20 - CLEANING PROCEDURE

27CE DECLARATION OF CONFORMITYCE DECLARATION OF CONFORMITYCE DECLARATION OF CONFORMITYCE DECLARATION OF CONFORMITYCE DECLARATION OF CONFORMITYHI 9912D

Strany 21 - TROUBLESHOOTING

MAN9912R106/01http://www.hannainst.comHANNA LITERATUREHANNA LITERATUREHANNA LITERATUREHANNA LITERATUREHANNA LITERATUREHanna publishes a wide range of

Strany 22 - ACCESSORIES

3PRELIMINARY EXAMINATIONPRELIMINARY EXAMINATIONPRELIMINARY EXAMINATIONPRELIMINARY EXAMINATIONPRELIMINARY EXAMINATIONGENERAL DESCRIPTIONGENERAL DESCRIP

Strany 23 - OTHER ACCESSORIES

4pH0120100200mVALARMpH0SECONDSmV2000TIMERMINUTES90PROPORTIONAL SETTINGS1102.557.50SECONDSpH2.00TIMERMINUTES90PROPORTIONAL SETTINGS1102.557.5500900CALA

Strany 24

53.8“96.9 mm25 mm1“75 mm3“Fig. 3227.8 mm9“188.6 mm7.4“221.8 mm8.7“174.8 mm6.9“Fig. 4Figure 3 is a dimensioned, bottom view of the Wall MountedControll

Strany 25 - WARRANTY

6FUNCTIONAL DIAGRAM HI 9912FUNCTIONAL DIAGRAM HI 9912FUNCTIONAL DIAGRAM HI 9912FUNCTIONAL DIAGRAM HI 9912FUNCTIONAL DIAGRAM HI 9912pH0120100200mVALARM

Strany 26 - OTHER PRODUCTS FROM HANNA

7Unplug the instrument from the power supply beforewiring or replacing the fuses.2324252617. Triple contact alarm in a Normally Closed (NC) or a Norma

Strany 27 - CE DECLARATION OF CONFORMITY

8Specifications HI 9912RANGE 0.00 to 14.00 pH and 0 to 1000 mVRESOLUTION 0.01 pH and 1mVACCURACY ±0.02 pH and ±5 mV(@20°C/68°F)TYPICAL EMC ±0.1 pH and

Strany 28 - MAN9912R1

9CONNECTIONS & WIRINGCONNECTIONS & WIRINGCONNECTIONS & WIRINGCONNECTIONS & WIRINGCONNECTIONS & WIRINGELECTRODE WITHBNC CONNECTIONW

Komentáře k této Příručce

Žádné komentáře