www.hannainst.com
This Instrument is in
Compliance with the CE Directives
Instruction Manual
HI 95715
Ammonia Medium Range ISM
Zobrazit stránku 0
1 2 3 4 5 6 ... 19 20

Shrnutí obsahu

Strany 1 - Ammonia Medium Range ISM

1www.hannainst.comThis Instrument is inCompliance with the CE DirectivesInstruction ManualHI 95715Ammonia Medium Range ISM

Strany 2 - TABLE OF CONTENTS

10The flashing digits indicate that:1) the month can be set2) the day can be set“Storage”: this prompt appears for 1 second at the end of thecalibrati

Strany 3 - PRELIMINARY EXAMINATION

11Under range. A blinking "0.00" indicates that the sample absorbsless light than the zero reference. Check the procedure and makesure you u

Strany 4 - ABBREVIATIONS

12• It is important that the sample does not containany debris. This would corrupt the reading.• In order to avoid reagent leaking and to obtainmore a

Strany 5 - PRECISION AND ACCURACY

13MEASUREMENT PROCEDURE• Turn the meter on by pressing ON/OFF.• When the LCD displays “715”, it is ready.• Fill the cuvet with 10 mL of unreacted samp

Strany 6 - PRINCIPLE OF OPERATION

14• Replace the cuvet into the holder and ensurethat the notch on the cap is positioned securelyinto the groove.• Hold READ/TIMER for three seconds. T

Strany 7 - FUNCTIONAL DESCRIPTION

15VALIDATION PROCEDURE• Turn the meter on by pressing ON/OFF.When the LCD displays “715”, it is ready.• Place the CAL CHECK Standard Cuvet A into theh

Strany 8

16CALIBRATION PROCEDURE• Turn the meter on by pressing ON/OFF.• When the LCD displays “715”, it is ready.• Enter the calibration mode by holding CAL C

Strany 9 - GUIDE TO DISPLAY CODES

17or• Press READ/TIMER and “SIP” will blink duringmeasurement.• The instrument will show for three seconds theCal Check standard value.Then the date o

Strany 10

18REAGENT SETSHI 93715-01 Reagents for 100 testsHI 93715-03 Reagents for 300 testsOTHER ACCESSORIESHI 95715-11 CAL CHECK Standard Cuvets (1 set)HI

Strany 11

19Recommendations for UsersBefore using these products, make sure that they areentirely suitable for your specific application and forthe environment

Strany 12

2TABLE OF CONTENTSPRELIMINARY EXAMINATION ...3GENERAL DESCR

Strany 13 - MEASUREMENT PROCEDURE

20MAN95715R1 09/03www.hannainst.com

Strany 14

3PRELIMINARY EXAMINATIONPlease examine this product carefully. Make sure that the instrument is not damaged. If anydamage occurred during shipment, pl

Strany 15 - VALIDATION PROCEDURE

4The HI 95715 is an auto diagnostic portable microprocessor meter that benefits from Hanna’syears of experience as a manufacturer of analytical instru

Strany 16 - CALIBRATION PROCEDURE

5Range 0.00 to 9.99 mg/L (as NH3-N)Resolution 0.01 mg/L for measurement0.1 mg/L for calibration and validationPrecision ±0.12 mg/L @ 6.00 mg/LTypical

Strany 17

6Absorption of Light is a typical phenomenon of interaction between electromagnetic radiation andmatter. When a light beam crosses a substance, some o

Strany 18 - BATTERY REPLACEMENT

7A microprocessor controlled LED emits radiation which is first optically conditioned and beamedto the sample contained in the cuvet. The optical path

Strany 19 - WARRANTY

8KEYPAD DESCRIPTION• ON/OFF: to turn the meter on and off.• ZERO: to zero the meter prior to measurement.• READ/TIMER: this is a bi-functional key, ju

Strany 20 - MAN95715R1 09/03

9This prompt appears for 1 second each time the instrument isturned on.This indicates that the meter is in a ready state and zeroing canbe performed.S